Sign In | Join Free | My xxjcy.com |
|
Brand Name : Supmeter
Model Number : BST106-B60S(L)
Certification : CE
Place of Origin : China
MOQ : 1pcs
Payment Terms : T/T, Western Union
Supply Ability : 1000pcs per month
Delivery Time : 3-20 working days
Packaging Details : 1pcs/box
Power supplier : DC24V
Loadcell : 8 loadcell connectable 350ohm
COM1 : RS232
Out put : 4-20Ma
Mini Weighing Force Measuring Controller With Force Display And Force DO Output Mode
Alarm Signs
Sign | Alarm Cause | Solution |
Err0 | Weighing Signal Type Error. | Power-on again after making sure that the set value of parameter [111] ‘Weighing Signal Type’ and the switch position of DIP1/DIP2 are matched with the actual weighing input signal. |
Err1 | RAM Failure | Replace the chip RAM. |
Err2.1 Err2.2 | EEPROM Failure. | Replace the chip EEPROM. |
Err3 | Unused. | |
Err4 | ADC Failure. | Replace the ADC module. |
Technical Specifiction:
Power Supply | AC24V±20% |
Display | 5 Red Led Digital Tubes for English&Digit Display |
Sampling Frequency | 1280Hz |
A/D Convert | 24-bit |
Keypad | 4 keys for Shortcut mode operation with key tone |
Excitation Voltage Output of Loadcell | DC5V |
Max. Connection number of Loadcell | 8 Loadcells (350Ω) |
[mV]Signal Input Range | 0-19.5mV |
DO | 2 Normally Open Transistor Switch Outputs |
AO | 1Analog Signal Output: 4~20mA. |
Communication Port | COM1:RS232;COM2:RS485 |
Outline Dimension | 107 × 60 × 100 mm (W×H×D) |
Net Weight | Approx. 1.2kg |
IP Grade | IP65 |
Verfication Accuracy | 0.03% |
Static Weighing/Force Measuring Accuracy | 0.2%~.5~ |
Mini Weighing Force Measuring controller with force display and Force DO output mode
If there is not any keypad operation in one minute and it’s not in the processes of ‘F2 System Calibration’ & ‘F6 Factory Adjustment’, the controller will return to ‘Main Display Interface’ automatically.
Menu Operation | |
Key Name | Description |
【MENU】 | Enter Main Menu. Exit. |
【ENT】 | Enter / Save / Alarm Acknowledge. |
【◄】 | Cursor shifts left. Display the previous option. |
【►】 | Cursor shifts left. Display the next option. |
【▲】 | Display the next interface or option. Digit input: +1 ( 0~9 loop). |
【▼】 | Display the previous interface or option. Digit input: -1 ( 0~9 loop). |
Quick Operation | |
【MENU】 【Ñ】 * |
|
【◄】 (【SET】) | Recipe parameters setting. |
【◄】 【ZERO】 【→0←】 * |
|
【▲】 【TARE】 【→T←】 * |
|
【ENT】 【G/N】 | Gross Weight / Net Weight display switch. |
![]() |
AC220V Load Cell Display And Controller 2 Normal Open / Closed Relays With Led Display Images |